P_HCMTM_64
QUESTION NO: 1
HR wants to monitor the maintenance of Personal Development (PD) master data.
Which methods are available to audit this? (Choose two)
A. Program RPUAUD00 for logged changes to standard infotypes 0001-0999.
B. Log of report starts accessing logical database PCH.
C. Log of report starts accessing logical database PNP.
D. Transaction PPOME for organization structure changes.
E. Program RHDOC_DISPLAY for logged changes to standard infotypes 1000-1999.
Answer: D,E
QUESTION NO: 2
Which areas are used by HCM Processes and Forms? (Choose two)
A. SAP Employee Interaction Center (EIC)
B. SAP Interactive Forms
C. SAP Business Workflow
D. SAP Network Process Integration (PI)
Answer: B,C
QUESTION NO: 3
An organization has the need to reduce their headcount. Therefore they need to identify jobs and positions that have to be retained based on critical business processes.
How can you determine what jobs and positions are critical?
A. Execute Complete Job Description (S_AHR_61016501) from Organizational Management Info System.
B. Execute Infotype Reporting (S_AHR_61016532) from Organizational Management Info System using Spec. Position Characteristics (infotype 1958).
C. Execute Profile Matchup (PEPM) from Personnel Development Info System.
D. Execute Complete Position Description (S_AHR_61016511) from Organizational Management Info System.
Answer: B
QUESTION NO: 4
After having set up structural authorizations, your customer is experiencing slow system response times.
How can you improve system response times?
A. Delete all entries of structural authorization indexes and recreate each structural authorization profile.
B. Generate indexes for users assigned to these structural authorizations using RHBAUS00.
C. Increase database storage capacity to better process the complex indexing associated with building and maintaining structural authorizations.
D. Reduce the number of structural authorization profiles to allow fewer users access to the structural authorization objects.
Answer: B
QUESTION NO: 5
Your customer needs a ‘Special Exempt’ indicator on ‘Job Attributes’ (Infotype 1610).
What do you recommend?
A. Change the data dictionary definition of a standard text field.
B. Change the field attribute on Dialog Database Assignment Table (T777D).
C. Configure the Screen Modification Table (T588M) and set the field as a radio button.
D. Customize the Infotype to add a radio button for the additional field.
Answer: D
C_TPLM30_66
QUESTION NO: 1
Which of the following are prerequisites for business completion? (Choose two)
A. The order must have actual costs.
B. The order must be fully settled.
C. The balance of the order must be zero.
D. The order must have planned costs.
Answer: B,C
QUESTION NO: 2
What information does the value category provide in the maintenance order?
A. The costs details for individual technical objects
B. The costs by work center
C. The material costs by valuation category
D. A summary of costs for multiple cost elements
Answer: D
QUESTION NO: 3
Which of the following Customizing settings is required to assign a notification to a maintenance order operation?
A. Assignment of operations to all object list entries active
B. Assignment of order type to notification type
C. Maintain indicator for notification data on order header
D. Create default value profiles for general order data
Answer: A
QUESTION NO: 4
When the user creates a maintenance plan for a call object (order), which value in the planning data determines the order type?
A. Priority
B. Maintenance activity type
C. Maintenance planner group
D. Main work center
Answer: C
QUESTION NO: 5
A maintenance technician replaces a defective counter with a new counter.
Before the users can create a standard measuring document for the new counter, what step(s) must they perform?
A. Create a new technical object to represent the new measuring point.
B. Create a special measuring document and set the Counter Replacement indicator.
C. Dismantle the old measuring point and create a new measuring point.
D. Create a new measuring point and change the measuring point from which the measurement reading was transferred.
Answer: B